Who's Online
There currently are 5459 guests and 1 member online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
;
Service manual in good quality, it was very helpful to me. Perfect service, I am very satisfied.
Jochen Kelm
;
Exellent manual ,it was in great condition,and got all the info i expected,5 stars!!
;
I searched the Internet exhaustively for this manual and Owner-Manuals was the least expensive...but provided an excellent reproduction within 4 hours. Very satisified.
20D2-S/G 21D1-S/G 21D2-S/G
DESCRIPTION OF SCHEMATIC DIAGRAM
SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE REPLACING PARTS. 2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OPERATING.
NOTES:
1. The unit of resistance "ohm" is omitted. (K = 1000 ohms, M = Mega ohm). 2. All resistors are 1/10 watt, unless otherwise noted. 3. All capacitors are µF, unless otherwise noted. (P = µµF).
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " å " ( ) ARE IMPOTANT FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAINTAINING THE SAFETY AND PERFORMANCE OF THE SET.
VOLTAGE MEASUREMENT CONDITIONS:
1. Voltages in parenthesis measured with no signal. 2. Voltages without parenthesis measured with 3mV B & W or Colour signal. 3. All the voltages in each point are measured with VTVM.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE ( �� - �� ) IS DIRECTLY CONNECTED WITH AC MAINS VOLTAGE. WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANSFORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE HAZARD OF ELECTRIC SHOCK.
WAVEFORM MEASUREMENT CONDITIONS:
1. The colour bar generator signal of 2.0V peak applied at of Base Video Buffer Amp. Q252. 2. Approximately 4V AGC bias .
31
|
|
|
> |
|