Who's Online
There currently are 6029 guests and 2 members online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Complete and very useful. Could have benefited from a little higher resolution on the schematic and layout diagrams for improved legibility.
;
Great Service Manual, Very Complete, as advertised, Perfect, Thanks!
;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
2. PURITY ADJUSTMENT
No. 1
Adjustment point PURITY ADJ.
Adjustment procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to ~700 µA . 2. Degauss the CRT enough with the degausing coil. Note: Follow the Job Instruction Sheet to adjust the magnetic field. Vertical Bv: +0.030 mT (0.30 gauss) Horizontal Bh: +0.020 mT (0.20 gauss) (Reference: page 3-6) Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. Observe the points a, b,as shown in Fig. 1-1 through the microscope. Adjust the landings to A rank requirement. Orient the raster rotation to 0 eastward. Tighten up the deflection coil screws. Tightening torque: 108 ± 20 N (11 ± 2 kgf) Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA. Note: Set to service mode by remote controller then press factory process R/C RGB key to change to RGB mono colour mode. For the following colours press R/C RGB(Hex 7E) key to change.
Waveform and others
a
b
3.
30mm
Fig. 1-1
30mm
4.
A
5. 6. 7.
B A=B
Fig. 1-2
Rank "A" (on the right of the CRT)
*
A
GREEN ONLY
BLUE ONLY Signal-colour screen cleared
RED ONLY
B A=B
Fig. 1-3
Rank "A" (on the left of the CRT)
* Press R/C RGB key for 1 second in NORMAL MODE, the colour will change to RGB mono colour mode.