Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
21HS-50N
� Geometry adjustment procedure
To adjust the geometry, follow the procedure outlined below: 1. Tune the set into a Philips test pattern. 2. Enter the service mode as described on page 6. 3. Use the channel up or channel down buttons to enter the desired mode 4. Use the volume buttons to achieve correct setting. 5. When adjustments are complete, use the standby button to turn off the set. The adjustment values will be stored at this point.
V-LIN Adjust the vertical linearity control so that the picture centring is as shown in figure 5.
Fig. 5 V-AMP Adjust the vertical amplitude control so that the picture overscans as shown in figure 6.
Fig. 6 V-CENT Adjust the vertical centring control so that the picture is centred as shown in figure 7.
Fig. 7 H-CENT Adjust the horizontal centring control so that the picture is centred as shown in figure 8.
Fig. 8