Who's Online
There currently are 5877 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site.
Thank you very much
21J-FG1RU
2. PURITY ADJUSTMENT
No. 1
Adjustment point PURITY ADJ.
Adjustment procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to ~700 µA . 2. Degauss the CRT enough with the degausing coil. Note: Follow the Job Instruction Sheet to adjust the magnetic field. Vertical Bv: +0.045 mT (0.45 gauss) Horizontal Bh: +0.020 mT (0.20 gauss) (Reference: page 3-6) Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. Observe the points a, b,as shown in Fig. 1-1 through the microscope. Adjust the landings to A rank requirement. Orient the raster rotation to 0 eastward. Tighten up the deflection coil screws. Tightening torque: 108 ± 20 N (11 ± 2 kgf) Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA. Note: Set to service mode by remote controller then press factory process R/C RGB key to change to RGB mono colour mode. For the following colours press R/C RGB(Hex 7E) key to change.
Waveform and others
a
b
3.
30mm
Fig. 1-1
30mm
4.
A
5. 6. 7.
B A=B
Fig. 1-2 Rank "A" (on the right of the CRT)
*
A
GREEN ONLY
BLUE ONLY Signal-colour screen cleared
RED ONLY
B A=B
Fig. 1-3
Rank "A" (on the left of the CRT)
* Press R/C RGB key for 1 second in NORMAL MODE, the colour will change to RGB mono colour mode.
3 � 15
|
|
|
> |
|