Description of SHARP 21SLX Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 DMRE85HP PANASONIC Service Manual by Greg Hatfield;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ICF6800W SONY Service Manual by Carlo Valli;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 MDS-B3 SONY Service Manual by Daryl Hamdorf;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 SR-636 SANSUI Service Manual by Dmitry Khazov;
Quick site processing. A complete and very useful manual with all details. Thank you!
 5100 NAD Service Manual by Bernhard Eickhoff;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar. Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.

Text excerpt from page 6 (click to view)
21SLX

SERVICE ADJUSTMENT
No. Adjusting point VCO adjustment: T203

PIF/AFT/AGC ADJUSTMENT
Adjusting procedure/conditions 1. Disconnect the antenna from the tuner antenna terminal. 2. Apply DC voltage to pin (4)(IF AGC) of IC201. » DC voltage: 6.0 V (allowable +0.1 V) 3. Using a digital voltmeter, measure the DC voltage at pin (20)(PLL FIL) of IC201. * The digital voltmeter must be able to take readings down to the third decimal place. 4. Relieve pin (4) of IC201 of the DC voltage. 5. Reconnect the antenna in position and receive the E-12CH signal. (With the AFT off, adjust the receiving frequency to 224.25 MHz.) 6. Connect the DC digital voltmeter to pin (20) of IC201. Adjust T203 so that the voltmeter should read the same voltage as in Step 3. Allowable error : 0.015 V (20 kHz) 1. Receive the E-12CH (PAL colour bar) signal. If this signal is not available, any signal above the E-5CH band is acceptable. » Field strength : 55-80 dBµV Make sure the frequency is almost the same as that of the received channel (±30 kHz). 2. Using the channel setting control, make a frequency of 224.25 MHz appear on the screen (the AFT turns off). If any other channel than E-12CH is received, make its frequency on the screen. (The AFT turns off when the on-screen display turns yellow.) 3. Turn T204 clockwise to have a 6-V point, and counterclockwise to have a 0.2-V point. Position the coil at the center of these two points. 4. Adjust T204 so that the DC voltage at pin (1) (AFT OUT terminal) of IC201 be 3.3 ±0.1 V. (See Fig. 3) 1. Receive the E-12CH (PAL colour bar) signal. » Field strength : 57 ±1 dBµV (75 ohms open) 2. Connect the oscilloscope to TP210, as shown in Fig. 4. Waveform and others * Warm up the unit for longer than 10 minutes in advance. 1

115V ADJUSTMENT
No. 1 Adjusting point 115V adjustment: R711 Adjusting procedure/conditions 1. Receive the E-5CH (monoscope pattern) signal. 2. Using the remote controller, call the P-NORM mode. 3. Connect a beam ammeter between TP602 and TP603. » Ammeter’s full-scale : 3 mA range » Ammeter’s positive (+) lead : TP603 » Ammeter’s negative (-) lead : TP602 4. Take the beam ammeter reading to make sure that the beam current is between 900 µA and 1100 µA. * If not, readjust the FBT screen control to obtain the beam current of 900-1100 µA . 5. Connect a digital voltmeter to TP701. 6. Adjust R711 so that the digital voltmeter should read 115 ±0.5 V. Waveform and others

* 10 kHz at about 0.007 V.

* Position the T203 core in the range in which the E-12CH signal can be received.

2

AFT adjustment: T204

6

PIF CHECKING
No. 1 Adjusting point Tuner IFT (preset): TU201 Adjusting procedure/conditions 1. Get the tuner ready to receive the E-9CH signal. but with no signal input. Adjust the PLL data. 2. Connect the sweep generator’s output cable to the tuner antenna. (RF sweep) 3. Adjust the sweep generator’s output level to 80 dBµV. 4. Connect the response lead (use a low-impedance probe with wave detector; see Fig. 1) to the tuner’s IF output terminal. (This terminal must have the probe alone connected.) 5. Set the RF AGC voltage to 0-6 V with no contact with the waveform. 6. Adjust the tuner IF coil to obtain the waveform as shown in Fig. 2. Note: Be sure to keep the tuner cover in position during this adjustment. Waveform and others 3 RF AGC cut-in adjustment: R216

* Turn the core counterclockwise for the UP direction, and clockwise for the DOWN direction. Adjust the T201 core to point B (between B’ and B”). (Points A and C are rejectable.) Note: If a 50ohm field strength meter is used without a 50/75 impedance converter, set the field strength to 55 ±1 dBµV. Pay attention to a loss that would be caused with the converter.

3. Turn R216 to have the highest voltage. 4. Turn R216 slowly in the opposite direction until the voltage goes down 0.1 V below the highest level. 5. Adjust the signal level to 63-67 dBµV and make sure there is no noise. 6. Now adjust the signal level to 90-95 dBµV and make sure there is no chrominance modulation beat.

6-1

6-2

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG-7500 PANASONIC
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

YB400PE GRUNDIG
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

HC-P4752W SAMSUNG
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-KN2000 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.174 - Number of Queries: 132 - Query Time: 0.034