Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 5829 guests online.
Categories
Information
Featured Product
Home >> SHARP >> 76GF63H Service Manual
 
 0 item(s) in your cart 

SHARP 76GF63H
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SHARP 76GF63H Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 CR5900 DUAL Service Manual by Eldin Isakovic;
I had a problem with the mains transformer, I did not know the voltages on the secondary, this manual helped me to solve this problem, thanks for the manual!
 QT70 SHARP Service Manual by Viktor Strogan;
Great manual, great quality copy, complete parts reference and scematics, Thank you
 21HT5403/01Z PHILIPS Service Manual by Matteo Vannini;
Very good as always. Also this manual appears clear and well processed. I know it will help me to work on this TV. Thank you a lot! Matteo
 RS2000 LOEWE Service Manual by Calcan Mugurel;
complete wiring diagram, without the part list. high quality copy. thanks for promptly.
 TX-300 FISHER Service Manual by Meyer M Rochwerger;
Well done scan of a useful manual. It will be useful in my workbench!!

Text excerpt from page 9 (click to view)
76GF-63H
Changing NVM Data To change the data contained within the Non Volatile Memory, it is necessary to first select the page the data is stored in, then the position and finally to change the data itself. The procedure below outlines this process. 1. While on ALTER NVM PAGE, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 2. Press the channel up button and ALTER NVM POSITION appears, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 3. Press the channel up button and ALTER NVM VALUE appears, use the volume up/down buttons to change this data (data is shown in hexadecimal format). 4. Once this data has been set, press the standby button to store. 5. If another NVM value has to be changed, use the channel down button to select the page or position and repeat as necessary. Note: DO NOT change any NVM data, unless you have been advised to do so by a Sharp representative. If data is incorrectly changed, serious damage may occur to the receiver.

Procedure to re-set the NVM: Modify the NVM values as in the below table.
NVM Page 00 0C 0C 0D 0D NVM Position 7E 20 61 3C A5 Default Value A5 Different on every set Different on every set Different on every set Different on every set New value A6 Default value + 1 Default value + 1 Default value + 1 Default value + 1

All the above values are hexadecimal. Contrast Adjustments Three types of contrast levels can be varied as listed below: � TELETEXT MIX MODE CONTRAST � TELETEXT CONTRAST � OSD CONTRAST Use the volume up/down buttons to adjust to a suitable level, then press the standby button to store. AGC Adjustment To correctly align the Automatic Gain Control, follow the procedure outlined below: 1. Tune the set into a pattern generator on CH10. 2. Adjust the signal strength of the pattern generator to 57uV 3. Enter the service mode. 4. Enter the AGC Adjustment menu. 5. Press the standby button on the remote control. 6. The adjustment will be carried out and stored automatically.

DVCO Adjustment (PAL) Carry out the DVCO Adjustment (PAL) as shown below: 1. Receive a Phillips pattern signal. 2. While in the DVCO ADJUSTMENT (PAL) menu, press the standby button. 3. The adjustment will be carried out automatically and stored.

AFT Adjustment To correctly align the Automatic Fine Tune, follow the procedure outlined below: 1. Tune the set into a pattern generator on CH69. 2. Enter the service mode. 3. Enter the AFT Adjustment menu. 4. Press the standby button on the remote control. 5. The adjustment will be carried out and stored automatically.

DVCO Adjustment (NTSC) No adjustment required.

Auto Installation On/Off To return the receiver to the original Auto Installation mode, using the volume up or down button, set the Auto Installation On/Off to On. This setting is automatically stored and when the receiver is turned on the next time it will start up in Auto Installation mode.

9

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EVO-9850 VOLUME 1 SONY
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.293 - Number of Queries: 133 - Query Time: 0.067