Manual is in German but complete. I needed this one to fix a long lasting problem with the internal PSU of the camera. Most of the capacitors begin to leak after a few years wich results in the inability to power on the camera. When you try to turn it on the power led flickers and the unit directly turns off. Thanks to this manual I was able to locate all bad cap's and to dis- and reassemble the camera without any problems.
Excellant, finally this is want I need and searching for The service manual is fantastic and thank you to owner-manuals.com and its service. Price is reasonable. It's a bit slow on my end in downloading but manage to receive the whole manual without a break. once again, thanks.
Text excerpt from page 15 (click to view)
AY/AE-A079E AY/AE-A099E
Table Y-6 [AY-A079E]
Lamps Step 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Output for outdoor unit OFF Compressor Reverse Valve Outdoor Fan Motor OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF (Back to step 1) 1 : 7�C : 7�C 2 : �2�C : �2�C 3 : 0.1V : 0.1V Room temp. 42�C (Room temp.) or (Room temp.) Pipe temp. 42�C (Pipe temp.) or (Pipe temp.) ON OFF ON OFF ON OFF RED 1 Flickering ON ON ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF ON ON OFF OFF OFF OFF OFF ON ON OFF YELLOW 2 ON OFF ON OFF 3 4 Indoor Fan motor OFF D H L D UL H M L OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Louver
OPEN OFF OFF CLOSE OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF
42�C
42�C
(P57 input voltage) 0.45V (P57 input voltage) or (P57 input voltage
0.45V)
4 : When Power on start is effective, Timer LED(yellow) is ON.