Who's Online
There currently are 5956 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
ecelent I was reciver the service manual soon I fell so happy very complete 100% positive all by this store tanks atte Luis salazar
;
A great copy of the manual, and the only one I could find anywhere on the net! The circuit diagrams are easily readable, all component values marked and easy to see. A highly appreciated download!
;
Great Manual. This manual is available no where else. It was exactly what I was looking for.
;
The TEAC A-1500's Service Manual was instrumental in reviving this classic reel-to-reel. Not only does it have the schematics, exploded parts diagram and parts list, it also provided mechanical adjustment information that approximate factory default settings.
;
This service manual was determinant to enable to fix my Alpine Amplifier. I am pleased with my purchase. For a 5 star rating I would like to see a higher resolution scan of the printed circuit board lay-out because the gray scale grafics was dificult to see. Also some schematic diagrams were scanned at a slight angle. Never the less, it had all information I needed to troubleshoot and service my equipment.
AY-AP18CE AH-AP18CE AE-A18CE AU-A18CE
AY-AP24CE AH-AP24CE AE-A24CE AU-A24CE
4.
Hot-Keep This function automatically controls the on-off operation of the indoor fan motor in accordance during the heating operation, thereby preventing the air conditioner from delivering a cold air when the compressor is off. When the room temperature exceeds the thermostat line �H1�, the compressor is turned off, and the indoor fan motor is turned off after rotating at �HUL� for 30 seconds. 3 minutes and 10 seconds after turning off the compressor, the indoor fan motor is turned on for 3 minutes and 20 seconds. At 10 seconds after turning on the compressor, the indoor fan motor is turned on. The next compressor OFF time is for 3, 8 or more than 8 minutes according to the room temperature (the time increases with a rise of room temperature) when 3 minutes elapse after turning on the compessor.
3 min. Compressor ON 3 min.
6. Overheating protection system When overloading occurs during the heating operation, this system controls the outdoor fan motor according to the indoor pipe temperature to prevent the overloading of the compressor and restrain the rise in high pressure. When the indoor pipe temperature exceeds U1�C, the outdoor fan motor is turned off, and when the indoor pipe temperature falls U2�C, the outdoor fan motor turns on.
OFF U1 ON
U2
U1 and U2 are defferent by the time. 1 within 3 minutes 3 over 3 minutes
Figure Y-9 Table Y-3
OFF Indoor fan motor ON OFF
30sec. 30sec.
HUL
HUL
MODELS
Fan LIne U1
HH 1 2 54�C 54�C 52�C 53�C 54�C 54�C
HAH
HM 2 53�C 52�C 53�C 52�C
1 2 1 54�C 54�C 53�C 52�C 53�C 51�C 54�C 54�C 53�C 52�C 53�C 51�C HL
Thermo off
10sec.
time
10sec.
U2 U1
Figure Y-7 5. Preheat air flow This function is intended to prevent cold air from being discharged when the heating operation starts or when defrosting. When the indoor pipe temperature is below 29�C at the begining of the heat operation or after defrosting, the indoor fan motor stays. When the indoor pipe temperature gets higher than 29�C, the fan motor is turned on at speed �HUL� after compensation of starting. When the indoor pipe temperature exceeds 35�C, the specified fan speed is restored. When the indoor pipe temperature falls below 30�C, the fan speed shifts down to "HUL". And, when the indoor pipe temperature falls below 23�C, the fan motor turns off. Then, over 29�C , it turns on again at speed �HUL�.
35
U2 MODELS Fan LIne U1 U2 U1 U2
52�C 53�C HAL 1 2 52�C 52�C 50�C 51�C 52�C 52�C 50�C 51�C
HUL 2 52�C 51�C 52�C 51�C
1 2 1 52�C 52�C 52�C 50�C 51�C 50�C 52�C 52�C 52�C 50�C 51�C 50�C
30 29 24
Pipe temperature(�C)
OFF
UL
Preset Fan speed
UL
OFF UL
Figure Y-8
21
|
|
|
> |
|