I didn't realise a manual for an early plasma TV such as the one we were gifted could be so easily obtained. No manual was supplied with it, and as senior citizens we were a little puzzled over some aspects of its use. I do not want a listing for your store credit as we are not fairly big computer users. The manual was well organised, as it should be, with its backing of the Pioneer name. The download was prompt and everything worked quite smoothly. Thank you. Gordon.
;
Thank you very much for the manual. It is what I needed and it will be very helpful to me. The delivery of the manual was easy and very fast. I strongly recommend this site to other users. Best regards.
XG-V10WE
AN-SD1E/S422E
No. 12
Adjusting point Video AGC adjustment
Adjusting conditions 1. Feed the split colour bar signal. 2. Select the following group and subject. Group : VIDEO1 Subject : AGC Make sure there are some bit dropouts on the screen. 1. Feed the split colour bar signal. Select the following group and subject. Group : VIDEO1 Subject : TINT 2. Connect the oscilloscope to pin (4) of P801.
Adjusting procedure » Using the set�s control switch or the remote controller�s button, adjust the setting so that the 100% white signal has some bit-less.
13
Video tint adjustment
» Using the set's control switch or the remote controller's button, adjust the setting so that the � (B�Y) waveform runs straight downhill.
14
NTSC colour saturation adjustment
1. Feed the split colour bar signal. 2. Select the following group and subject. Group : VIDEO1 Subject : N-COLOUR 3. Connect the oscilloscope to pin (1) of P801.
» Using the set�s control switch or the remote controller�s button, adjust the setting so that the amplitude between the 100% white and red levels be 0.20 ± 0.02 Vp-p. 100% White Red
15
PAL colour saturation adjustment
1. Feed the PAL colour bar signal. 2. Select the following group and subject. Group : VIDEO1 Subject : P-COLOUR 3. Connect the oscilloscope to pin (1) of P801.
» Using the set's control switch or the remote controller�s button, adjust the setting so that the amplitude between the 100% white and red levels be 0.36 ± 0.02 Vp-p.
100% White Red
16
SECAM colour saturation adjustment
1. Feed the SECAM colour bar signal. 2. Select the following group and subject. Group : VIDEO1 Subject : S-COLOUR 3. Connect the oscilloscope to pin (1) of P801.
» Using the set's control switch or the remote controller�s button, adjust the setting so that the amplitude between the 100% white and red levels be 0.50 ± 0.02 Vp-p.
100% White Red