Who's Online
There currently are 5835 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Complete service manual in very good scanning quality with all schematic and PWB graphics as well as assembly & maintenance instructions. A slight drawback is that the rastering of the PWB graphics sometimes makes it a bit difficult to follow fine traces, but no showstopper.
;
Purchased the manual that I was looking for at a great price and could download it easily.. Great service experience and for future purchases I plan to use the site. Thank you very much
;
Service manual in good quality, it was very helpful to me. Perfect service, I am very satisfied.
Jochen Kelm
;
Exellent manual ,it was in great condition,and got all the info i expected,5 stars!!
;
I searched the Internet exhaustively for this manual and Owner-Manuals was the least expensive...but provided an excellent reproduction within 4 hours. Very satisified.
ADJ 6
Copy image distortion adjustment
3) Loosen the pulley angle fixing screw on the front frame side of the scanner unit B.
This adjustment must be performed in the following cases: � When the scanner (reading) section is disassembled. � When a copy image distortion occurs.
ADJ 6A
Scanner (reading) unit parallelism adjustment
1) Loosen the screw that is fixing the scanner unit A and the drive wire, and remove the scanner unit A from the drive wire.
4) Adjust the pulley angle position on the scanner unit B front frame side so that both stoppers on the front frame and the rear frame are in contact with the scanner unit B at the same time. 5) Fix the pulley angle on the scanner unit B front frame side. If the above procedure does not result in a satisfactory result, perform the following procedure. Loosen the fixing screw of the scanner unit drive pulley that is not in contact. Without moving the scanner unit drive shaft, manually turn the scanner unit drive pulley so that the scanner unit B is brought into contact with the stopper on the front frame side and the stopper on the rear frame side at the same time. (Change the relative positions of the scanner unit drive pulley and the drive shaft.) Fix the scanner unit drive pulley fixing screw.
Scanner unit B
2) Manually turn the scanner drive pulley to bring the scanner unit B into contact with the stopper. At that time, if the scanner unit B makes contact with the two stoppers on the front and the rear frame simultaneously, the parallelism of the scanner unit B is proper. If not, perform the following procedures.
Winding pulley
AR-C260/C260M SETTING AND ADJUSTMENTS 8 - 16
|
|
|
> |
|