CD-BK2100V
Check the TE waveform at pin 18 on IC1.
If the waveform shown in Figure 45-1 appears and soon after NO DISC appears. No "Initialization" is possible, but play is not possible. No Yes The tracking servo is not activated. Check the peripheral circuits at pins 18 and 19 on IC1, pin 23 on IC2, and CNS1A/B.
Yes
A normal jump operation cannot be completed or the beginning of the track cannot be found. Check the around pin 23 on IC2.
"Initialization" is not possible.
Data cannot be read. Check the VCO-PLL system.