Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 5169 guests online.
Categories
Information
Featured Product
Home >> SHARP >> SF-2540 Service Manual
 
 0 item(s) in your cart 

SHARP SF-2540
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of SHARP SF-2540 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 A-X420 BK PIONEER Service Manual by Tim Ward;
Exactly what I needed to be able to bring the amp back to life... will come back to this site the next time I need schematics.
 XM-3040 SONY Service Manual by Dexter Aqui;
Information was accurate and very helpful. However the continuity made it a little difficult to follow from one page to the next.
 KV21M3A SONY Service Manual by Matteo Vannini;
Very very good as usual very trustable site. Perfect!!!!!!
 KM394 NORDMENDE Service Manual by Edgar Proppe;
The Service Manual received was helpful. Good copy of original document.. I recomend all of my friends about this technical page.
 KDCM907 KENWOOD Service Manual by Endre Kajari;
Perfect, complete manual, exactly what I needed. Recommended to everyone.

Text excerpt from page 31 (click to view)
SF-2540 Main code 52 Sub code 01 Description Ref. Page

°

ADU alignment plate adjust value setup Used to adjust the home position of the ADU alignment plate. When the test command is executed, the READY lamp turns on. Enter a new value as the previously set value came displayed, and press the PRINT switch to stored it in memory. It is adjustable from 1 to 99. The default is 7. Setting a smaller value increases the width of the alignment plate and vice versa. ADU rear plate adjust value setup Used to adjust the home position of the ADU rear plate. When the test command is executed, the READY lamp turns on. Enter a new value as the previously set value came displayed, and press the PRINT switch to stored it in the memory. It is adjustable from 0 to 99. The default is 0. Setting a smaller value increases the width of the rear plate and vice versa.

02

°

03

ADU drive clutch off time setup: 1ms increment (1 step) 0 � 10 1 = 1ms, ��� 18 = 18ms, ��� 99 = 99ms Setting a smaller value shortens the ADU clutch off timings and decreases the enforced curling rate of paper.

53

01

°

RADF stop position adjustment value (normal paper, single copy) setting Used to adjust the RADF stop position in single copy with normal paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (normal paper, duplex copy) setting Used to adjust the RADF stop position in duplex copy with normal paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (thin paper, single copy) setting Used to adjust the RADF stop position in single copy with thin paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF stop position adjustment value (thin paper, duplex copy) setting Used to adjust the RADF stop position in duplex copy with thin paper. When this simulation is executed, the ready lamp lights up and the currently set adjustment value is displayed. Enter the new adjustment value and press the PRINT switch to store it in the memory. The adjustment value should be in the range of 0 to 15. RADF resist sensor adjustment Used to adjust the RADF resist sensor. (In the case of ADF, the resist sensor and the paper pass width sensor are adjusted.) When this simulation is executed, the RADF resist sensor is adjusted and the adjustment value is displayed.

02

°

03

°

04

°

05

°

06

°

RADF timing sensor adjustment Used to adjust the RADF timing sensor. When this simulation is executed, the RADF timing sensor is adjusted and the adjustment value is displayed. RADF repulsion sensor adjustment Used to adjust the RADF repulsion sensor. When this simulation is executed, the RADF repulsion sensor is adjusted and the adjustment value is displayed. RADF empty sensor adjustment Used to adjust the RADF empty sensor. When this simulation is executed, the RADF empty sensor is adjusted and the adjustment value is displayed.

07

°

08

°

8 � 17

1/27/1999

You might also want to buy

$4.99

SF2540 SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

SF-2540 SHARP
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.197 - Number of Queries: 111 - Query Time: 0.039