THIS MANUAL IS VERY GOOD AND VERY CLEAR
PLEASE NOTE IT DOES NOT CONTAIN THE SETUP INFORMATION TO ALIGHN THE GEARS IN THE CD MECH IT DOES SHOW ALL THE PARTS AND THEIR LOCATIONS .
;
Complete service and operation manual. All schematics are there, all circuit boards AND add-on boards. Including exploded views ,component names and specifications. Also electrical and mechanical adjustment procedures are in this manual. This manual also covers the more advanced BR-S811E unit. Scan quality is fair and usable.
;
High quality scan of original Service Manual. Everything´s fine!
;
Good scan of the original service manual. All schematics and adjustment procedures are there. It helped me to fix a long lasting problem with the tracking circuitry. The manual also includes the supplementals 1,2 and 3. Included are; electrical schematic's , pcb layout's, mechanical drawing's and exploded views, disassembly manual and maintenance procedures. 236 pages.
;
The Service Manual received was helpful. The electronic information is exactly what I needed.
I recomend all of my friends about this technical page.
VC-SA32 VC-SA37 VC-SA54
ADJUSTMENT OF TAPE DRIVE TRAIN
1. Tape run rough adjustment 1 Remove the cassette housing control assembly. 2 After shortcircuiting TP801 provided at the center (facing to the main PWB), plug in the power cord. 3 Check and adjust the position of the tension pole. (See page 16.) 4 Check and adjust the video search rewind back tension. (See page 15.) 5 Connect the oscilloscope to the test point for PB CHROMA envelope output (TP201). Set the synchronism of the oscilloscope to EXT. The PB CHROMA signal is to be triggered by the head switching pulse (TP201 pin 2). 6 Set the alignment tape (VROCPSV) to play. (Put a 500g weight on the cassette tape to prevent lift of cassette tape.)
Guide roller Cassette Tape
Notes: 1. Previously set the tracking control in the center position, and adjust the envelop waveform to maximum with X value adjustment nut. Thereby the tape run rough adjustment is facilitated. 2. Especially the outlet side envelope waveform must have higher flatness.
Figure 4-32. 2. Adjustment of A/C head height and azimuth 1 Perform the initial setting of A/C head position by the method stated in "Page 18 Replacement 3". 2 Connect the oscilloscope to the audio output terminal. 3 Using the alignment tape in which 1 kHz linear audio signal has been recorded, adjust the height screw so as to get max audio output. 4 Using the alignment tape in which 6 kHz linear audio signal has been recorded, adjust the azimuth screw so as to get max audio output. 5 Repeat the above adjustment steps 3 and 4 a couple of times. Finally take the step 4 again.
500g
Weight of 500g
Figure 4-31. 7 Press the tracking button (+), (�) and change the envelope waveform from max to min and from min to max. At this time make sure that the envelope waveform changes nearly parallel. 8 Unless the envelope waveform changes nearly parallel, adjust the height of supply side and take-up side guide roller so that the envelope waveform changes nearly parallel. (For envelop adjustment procedure refer to Figure 4-35.) 9 Turn the tilt screw to remove the tape crease at the fixing guide flange. Play back the tape and check for tape crease at the fixing guide flange. (1) If there is no tape crease Turn the tilt screw clockwise so that tape crease appears once at the flange, and then return the tilt screw so that the crease disappears. (2) If there is tape crease Turn counterclockwise the tilt screw so that the tape crease disappears. (Reference) If the tilt screw is turned clockwise crease appears at the lower flange.
For X value adjustment Adjust the X value, turning the geartype screwdriver.
Figure 4-33.