Who's Online
There currently are 5795 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
XV-Z9000U/E
When the DMD unit has been replaced
Note: DMD chip and Formatter PWB are supplied at the same time, and an exchange only with DMD isn't done.Refer to "REMOVING OF MAJOR PARTS" when exchanging Formatter PWB. There is no need to readjust the back focal distance of the projection lens. If focusing is noticeably poor, however, make this readjustment. (1) (2) (3) (4) (5) (6) (7) Provide a distance of 2.4 m between the set and the screen. Adjust the lens shift until the projection lens comes to the same level as the center of the screen. Detach the optical unit top cover A from behind the projection lens. Loosen the four hex screws B in the back of the projection lens. Adjust the zoom knob at the front of the projection lens to �tele end� and ensure good focusing. Then adjust the zoom knob at the front of the projection lens to �wide end�. Insert the adjustment screwdriver C (9EVDRIVERZ9000) in the hole D at the back of the lens. Put the center of the screen in the best focus. (Preferably feed the SXGA signal for 1-dot white crosshatch pattern or 1-dot white dot pattern on black background.) (8) Move the zoom knob from �wide end� back to �tele end� and see if focusing is ensured. If not, repeat the above steps (5), (6) and (7) until the best focus is achieved. (9) Tighten the four hex screws B to the torque of 0.3 Nm (3.06 kgfcm), and apply screw loctite to them. (10) Attach the optical unit top cover A back into position. Finally fix the two screws E and apply screw loctite to them.
E E
A
C
X
B D
B
B B
Expansion figure of part X