Description of SHARP Z830 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages:

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 1300 NAD Service Manual by Heiko Rahnenführer;
complete part-lists and pcb layout, schematic diagram is good enlargable,
 EVOLUTION REVOX Service Manual by Sergey Yakushenko;
Excellent, fast delivery, excellent product. Good luck!
 DP-86DA MITSUBISHI Service Manual by Sam Kapasi;
This manual is for the usa model only. But it is clear , accurate and comprehensive, including board layouts and schematics. I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
 TYPE 2904 BANG&OLUFSEN Service Manual by Wayne Ezyk;
Great to have extra resources for Service Manuals, Now days you can really not trouble shoot efficiently without one , Wayne at IRIONS TV & ELECTRONICS REPAIR Clearwater , Fl. 33755 727-446-7955
 A-103 TEAC Service Manual by Mike Dunn;
For five bucks you can barely buy a hamburger. Or for the same five bucks you can buy a service manual. Much more useful. (and better for your health, depending on where you buy your hamburgers). Yes, there are free manual sites out there, but if they don't have what you want, you have to pay. And five bucks isn't much. Not for full specs, schematics and adjustment and parts replacement procedures. My only criticism is that grayscale illustrations aren't well rendered, but I've seen worse. Schematics and text are clear. I'll be happy to purchase from here again. Mike mikeinthemountains@gmail.com

Text excerpt from page 87 (click to view)
(V)
V1

CLV
0V

60Hz

50Hz

a
V2 Pulse ON time 0V
CPU output (CLPWM)

(msec)

â¢
V3

The shorter the pulse ON time is, the higher the CLV is, and vice versa. The pulse ON time rises at the zero-cross timing of AC and is driven with duty. Positive pulses the copy lamp ON signal are generated by C248 (C253) at falling of the CPU output and inputted to the photo triac through the 2-stage transistors.

â¢
0V

â¢

b
+5V

(11) Power section
This model is provided with the auto shut-off mode. The power section is also designed for it. When the power switch of the copier is turned on and the AC power is supplied, AC waveforms for +5V power are generated in the secondary side of transformer T301. The AC waveforms are full-wave-rectified and smoothed by diode BD102 on the main PWB side, and 5V is generated by 3-terminal regulator of IC111. The 5V power is supplied to the CPU. When the CPU is actuated by the 5V power, it starts the switching power to output the SWPEN signal (CPU output: LOW). The switching power outputs voltages of 24V and VBS with this signal. BVS is stabilized by IC112 to become a voltage with stable BV, and is used for LED display. 24V is supplied to the motor and the solenoid, and supplied also to the 3-terminal power for 5V through D144. When the CPU turns off SWPEN to enter the auto power shut-off mode, 24V and VBS output falls near zero, virtually turning off.

V4 0V

V5

0V

VCL

0V
Main switch (MSW)
T301

Main PWB
BD102 SINB60

IC111 7805

5V C107 47µF

C111 2200µF

* At rising of the CLPWM signal (V4), the coy lamp is switched by the triac. The trigger signal Cl is sent to the triac to turn on the lamp. Then the lamp is turned off at the zero-cross point of V1 waveform. The CPU reads the control voltage level (QV) corresponding to the change in the copy lamp voltage The CLV produces the waveform equivalent to the copy lamp voltage waveform which disables the full-rectified waveform of AC input during the pulse ON time. The waveform is converted to the DC level by the low pass filter composed of C102 and R105, and inputted to the CPU. The relationship between the CLV and the pulse ON time is shown in the figure below.

AC PWB

DC power unit
24V

D144 1N4004E

GND V8S IC112 7808 5V
1SWPEN

8V C105 47µF

IC101 CPU

DTC123JKA

C106 47µF

8 or 10 msec
Q209

Pulse ON (Varies)

12 â 10

You might also want to buy

$4.99

Z-830 SHARP
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

Z-830 SHARP
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.177 - Number of Queries: 112 - Query Time: 0.029